Measuring 2000 V Directly: Yokogawa WT1500 and How It Compares with WT5000 and WT1800R
Above 1500 V, most power analyzers have needed an external high-voltage divider, which adds wiring, cost and uncertainty. Yokogawa’s WT1500 is the first WT-series analyzer to accept 2000 V DC directly. Since the WT1500 is now on sale, this article looks past the launch news and asks a practical question: how does it compare with the WT5000 and WT1800R, and when is a pre-owned WT analyzer the smarter buy?
What Yokogawa launched with the WT1500
Yokogawa Test & Measurement announced the WT1500 Precision Power Analyzer on July 22, 2026, with sales starting August 19, 2026. The key points from the announcement:
- The first WT-series model to support 2000 V DC input.
- Total power accuracy of ±0.038% (DC, 50/60 Hz) and low-power-factor accuracy of ±0.07% of apparent power at 50/60 Hz.
- Two input element types that can be mixed in one unit: a high-voltage element that measures up to 2000 V DC directly with 300 kHz bandwidth, and a wide-bandwidth element up to 1000 V with 2 MHz bandwidth.
- Up to four power measurements and four motor evaluations, with encoder and resolver inputs.
- IEEE 1588 time synchronization, CAN/CAN FD data output and low-latency UDP data transmission.
- A 2U, 19-inch-wide chassis about 88 mm high.
- Up to five units can be synchronized for 20-channel measurement; Yokogawa lists multi-unit synchronization as an optional feature scheduled for release within 2026.
Why 2000 V direct input matters for xEV and energy storage
The problem with external dividers
Battery energy storage systems (ESS), power conversion systems (PCS) and the latest high-voltage vehicle platforms are moving above 1500 V. With a conventional analyzer, that means an external divider in the voltage path. The divider has its own ratio error, temperature drift and frequency response, all of which add to the uncertainty budget, and it adds connections that must be wired and checked safely. Measuring directly removes a component from the chain and makes the setup easier to document.
Power plus resolver in one instrument
Motor efficiency testing has often meant measuring electrical power on one instrument and rotor position on another, then aligning the data on a PC. Yokogawa says the WT1500 accepts resolver and encoder signals directly, so electrical and mechanical quantities share one time base. For e-axle and inverter work, that removes a common source of synchronization error.
WT1500 vs. WT5000 vs. WT1800R
| WT1500 (new) | WT5000 | WT1800R | ITECH IT9100 series | |
|---|---|---|---|---|
| Positioning | High-voltage xEV and energy | Flagship precision analyzer | High-performance, general purpose | Alternative brand |
| Direct DC input | Up to 2000 V (high-voltage element) | Below 2000 V class | Below 2000 V class | See product page |
| Basic power accuracy | ±0.038% total power (DC, 50/60 Hz) | ±0.03% basic power accuracy | 0.05% of reading + 0.05% of range | See product page |
| Power inputs per unit | Up to 4 | Up to 7 swappable elements | Up to 6 | See product page |
| Motor evaluation | Up to 4, encoder and resolver | Up to 4 motors | Yes | See product page |
| Sampling | Not stated in announcement | 10 MS/s, 18-bit; 1 MHz power bandwidth | 2 MS/s, 16-bit | See product page |
| Harmonics | Not stated in announcement | Up to 500th order | Up to 500th order (50/60 Hz) | See product page |
| Available from TXRX | Not listed | WT5000 | WT1800R | IT9100 |
WT5000 and WT1800R figures come from Yokogawa’s product pages. “Below 2000 V class” reflects Yokogawa’s statement that the WT1500 is the first WT model with 2000 V DC input; check each model’s datasheet for its exact voltage ranges.
When the WT5000 still makes sense
If you need many phases in one chassis, the highest basic accuracy in the WT family, or detailed harmonic and waveform analysis, the WT5000 remains the reference instrument. Seven swappable elements make it flexible for multi-phase inverter and motor rigs, and its modular design means a pre-owned unit can often be reconfigured with different elements.
When a WT1800R is enough
For efficiency, standby power and harmonic testing on systems well within its voltage ranges, the WT1800R covers most bench work. Its two element types (5 A and 50 A) let one unit handle both low-power and higher-current tests.
Buying a pre-owned power analyzer

Yokogawa WT1800R: representative image from the product page.
What to check
- The number and type of input elements actually installed, read from the instrument.
- Options such as motor evaluation, harmonics and data streaming, confirmed on the option screen.
- Current sensors, sensor power and adapters: high-current work usually needs external sensors, and they need their own calibration.
- Calibration certificate with measured data, and the date of the last calibration.
- Firmware version and whether newer features need an update.
- The condition of the input terminals and safety covers.
Related bench gear
A power analyzer is rarely used alone. Typical companions are electronic loads, AC/DC power supplies and current probes such as the Keysight N2893A and Keysight N7026A for waveform checks on an oscilloscope.
よくある質問
What is a precision power analyzer used for?
It measures voltage, current, power, power factor, efficiency and harmonics with high accuracy, typically on inverters, motors, chargers, power supplies and renewable energy equipment.
Can the WT1500 measure 2000 V without a divider?
Yes. Yokogawa states that the high-voltage element measures up to 2000 V DC directly, so no external high-voltage divider is needed in systems up to that level.
Should I buy a new WT1500 or a pre-owned WT5000?
Choose the WT1500 if you need direct measurement above the WT5000’s voltage ranges or resolver input in a compact chassis. Choose the WT5000 if you need more phases, top-tier accuracy and detailed harmonic analysis at lower voltages. A pre-owned unit can stretch the budget further.
What accessories do I need for current measurement?
For the WT1500, Yokogawa lists CT-series penetration-type sensors, the CT1000S split-core sensor and AC current clamp probes, used with new current adapters. For other models, check the sensor and power-supply options in the model’s documentation.
Bottom line
The WT1500 fills a real gap for 1500 V-plus systems, and its built-in resolver input simplifies motor testing. For many labs, a well-configured WT5000 or WT1800R still covers the work, and buying pre-owned can free budget for current sensors and calibration. Browse our power analyzers and current probes, or contact us for a quote.
出典: Yokogawa Test & Measurement, “Yokogawa Test & Measurement Releases WT1500 Precision Power Analyzer”, July 22, 2026 (sales from August 19, 2026). Original announcement: https://tmi.yokogawa.com/news/press-releases/2026/yokogawa-test-measurement-releases-wt1500-precision-power-analyzer/. WT5000 and WT1800R figures: Yokogawa WT5000 product page and Yokogawa WT1800R product page.
This article is an independent summary and commentary by TXRX. Quoted passages are attributed to Yokogawa Test & Measurement. All trademarks belong to their respective owners. TXRX is an independent supplier of new and pre-owned test equipment and is not affiliated with, endorsed by, or an authorized distributor of Yokogawa Test & Measurement.
TXRXについて — TXRX supplies new and pre-owned RF, microwave, optical and high-speed test instruments to labs and manufacturers worldwide. TXRX pre-owned equipment comes with a 6-month warranty; new equipment carries the manufacturer’s standard warranty. Learn more about TXRX · Contact us for a quote
Drafted with AI assistance and reviewed by the TXRX team.